Model 6011 Recording current meter
The Niskin Winged
Current Meter, has no external moving parts that can be clogged, fouled or
dislodged.
Principle of Operation: Winged housing is turned
in the direction of the flow and swept away from the vertical by the water
current; a measurement of the magnitude and direction of the tilt provides speed
and direction of the current. The standard sensors are inside an aluminum
housing protected from waterborne debris and rough handling. The standard meter
is equipped to record current speed, direction and temperature. Optional
pressure and conductivity sensors available.
Features:
Specifications:
Burst Sampling: 1, 2, 4, 8, 16, 32 readings
per burst at intervals of 2, 4, 8 seconds.
Speed range: 0-300 cm/sec.
Velocity: Threshold +2 cm/sec. Interchangeable wings provide optimum data
resolution for anticipated current speeds.
Data Storage: Removable
RAM cartridge 64k, 128k, 256, and 512k. RAM cartridge downloads to IBM PC/XT/AT,
using RAM Reader Kit (Model 6011RR).
Direction: Three-Axis Fluxgate
compass 0-360 degrees accuracy ± 2 degrees; resolution 1 degree.
Battery: Lithium Cells (2) -1 year or 40,000 32 sample averages.
Activation: Turn-on switch on the outside of the pressure housing.
Operational Depth: 5000 meters
Time Reference: Solid-state
crystal controlled oscillator; ± .1 sec/day accuracy - GMT absolute.
Measuring System: During the measuring period, signals from the
sensors are digitized and placed in memory together with the time code. The data
is shifted serially into the RAM memory cartridge.
Attachment Method:
Clamp-on motion-compensating standoff. View Typical Mooring Configruations: 6011deply.jpg
Sampling
Interval: 10 position switch selectable from 7.5 seconds to 1 hour.
Weight in Air: 9Kg (20lbs);
Length: 51.4cm (20.25")
Diameter: 10.5cm (4.125").
Sensor type Range Accuracy Resolution
Speed Force-balance 0-300 cm/sec 1 cm/sec. 1 cm/sec.
tilt sensorDirection Three-axis flux 0-360 degrees +/- 2 degrees 1 degree
gate compass Temperature Aged linear -5 C to +45 C .25 C 1/64 C
thermistorConductivity Inductive toroid 0-75 mS/cm. 2.5mS/cm. 1 mS/cm.
Pressure Strain gauge 0-6000 meters .5% of depth .1% of depth
Download a Manual download/MODEL
6011 MK II.pdf
Return to the Product Catalog